Kontaktai

8 683 44482 info@fogsat.lt

K. Petrausko g. 7, Kaunas

Prekių krepšelis

0,00 €

Kabeliai , Jungiamieji kabeliai , Jungtys
Partneriai

Openbox SM-200 -

Openbox SM-200 -

Išpardavimas!!!

Profesionalus palydovų paieškai skirtas įrenginys Openbox SM-200. Tai akumuliatoriumi arba elektra maitinamas prietaisas, kurio ekrane galima stebėti ne tik atskirų palydovų, bet ir transpoderių signalus. Suderinama su daugeliu LNB konverterių tipų, bei DiseqC pozicijų.

Techninės charakteristikos:

  • Frequency range: 930-2250MHz
  • Direct selection: memory plan, program, frequency, LNB, DiSEqC via front panel keypad
  • Memory: plan, program, transponder, frequency, LNB, DiSEqC, local oscillator frequency
  • Frequency resolution: 0.1 MHz
  • Input impedance: 75 ohm
  • Input connector: "F" ("CEI", "BNC" or "N" - option)
  • RF input power: OFF, +13 V, +18 V, 22 kHz (0.3 A) (ON/OFF button)
  • DiSEqC 1.1: Pre-programmed 4, 8, 12 or 16 "a.b.c.d" polarization positions in sequence, easy to use. Supports any type of LNB (analog or DiSEqC, single or dual power) and any type of multi switch (analog or DiSEqC 4, 8, 12, 16 directions and SCR LNB)
  • Dynamic analog RF level measurement: 35 to 120 dBuV, -25 to +60 dBmV (selectable) with limit indication: level too low, level too high
  • Measurement resolution: 0.1 dB
  • Level Measurement Accuracy: typ. 1.5 dB (max. 2.5 dB) with software correction (5 minutes after start-up)
  • Measuring filter bandwidth in SAT mode: 4 MHz at -3 dB
  • Measurement stability when operating in the temperature range from -10 to 50˚С: 0.1 dB/˚C
  • LNB frequency selection: from 0 to 20.000 MHz for bands "L" (direct reading IF-SAT), "S", "C", "KU", "KA";
  • QPSK (DEMODULATED MEASUREMENTS)
  • Frequency range: 930-2250 MHz
  • Direct selection: memory plan, program, frequency, LNB, DiSEqC via front panel numeric keypad
  • Memory: plan, program, transponder, frequency, LNB, DiSEqC, LO frequency, standard, symbol rate
  • Frequency resolution: 0.1 MHz
  • Input impedance: 75 ohm
  • Input connector: "F" ("CEI", "BNC" or "N" - option)
  • RF input power: OFF, +13V, +18V, 22KHz (0.3A) (ON/OFF button)
  • DiSEqC 1.1: Pre-programmed 4, 8, 12 or 16 "a.b.c.d" polarization positions in sequence, easy to use. Supports any type of LNB (analog or DiSEqC, single or dual power) and any type of multi switch (analog or DiSEqC 4, 8, 12, 16 directions and SCR LNB)
  • Dynamic digital level measurement at RF input: typ. value 35 to 120 dBuV, typ. value from -30 to +60 dBmV (selectable) with indication of limits: level too low, level too high (too low level, too high level)
  • Power measurement resolution: 0.1 dB
  • Level Measurement Accuracy: typ. 1.5 dB (max. 2.5 dB) with software correction (5 minutes after start-up)
  • Noise margin measurement error: typ. 0.5 dB (max. 1dB) with software correction
  • Measuring filter bandwidth in SAT mode: 4 MHz at -3 dB
  • Measurement stability when operating in the temperature range from -10 to 50˚С: 0.1 dB/˚C
  • QPSK symbol rate: 2 - 45 MSym/s (in 1Ksym/s increments)
  • BER measurement before and after Viterbi:
  • - bBER: up to 2 x 10-5
  • - aBER: 2 x 10-8
  • FEC, automatic selection with reading of the received value: FEC 1/2, 2/3, 3/4, 4/5, 5/6, 6/7, 7/8, 8/9
  • Automatic signal quality test: FAIL, MARGINAL, PASS
  • Noise margin measurement: -1 to 12 dB using a special algorithm that automatically takes into account FEC
  • LNB frequency selection: from 0 to 20.000 MHz for "L" (direct reading IF-SAT), "S", "C", "KU", "KA" bands.
  • QPSK standard selection: DVB/DSS
  • NET. ID. AND LIST OF MPEG SERVICES/PROGRAMS
  • Names of programs (services), bouquets and transponders, encryption system, orbital position and date are presented.
  • SAT SPECTRUM ANALYSIS
  • Frequency range: 930-2250 MHz
  • Span (span): 50-100-200-500-FULL
  • dB/div: 5
  • Dynamic Range: >30dB
  • Measurement resolution: 0.1 dB
  • Measurement filter bandwidth: 4 MHz at -3 dB
  • Reference level: 0 to 120 dBhV, -60 dBmV to +66 dBmV
  • Reference level setting: automatic and manual
  • Selecting other spectrum parameters:
  • - MAX HOLD (peak memory)
  • - SAT POINTING (optimal automatic pointing of a satellite dish)
  • DIFFERENT
  • Beep: when level or quality is selected (on/off button)
  • Food:
  • - Built-in rechargeable batteries: 7.2 V x 2.5 A (NiMH)
  • - external voltage: 12 Vac or 12 Vdc (1A) (connector: Ø 5.5 x 2.2)
  • - AC/AC adapter: 230 Vac, output: 12 Vac (supplied)
  • Battery autonomy at 25°C: 4 h depending on LNB consumption
  • (9 hours - opt.).
  • Battery discharge indication: sound signal and display on the graphic display, automatic shutdown of the meter by the microcontroller
  • Indication of the degree of charge of the batteries: on the display
  • Battery charging time: 1 h - 50%, 3/6 h - full charge
  • Size: 80 x 225 x 215 mm
  • Weight: 1.3 kg including batteries, bag and accessories
  • Housing: ABS plastic, dustproof, waterproof, shockproof
  • USB interface: for connecting to a PC; the ability to update the software via the Internet (changing the configuration of the memory plan, printing measurements, etc. - optional)
  • B/W graphic

45.- Išpardavimas €Kiekis:

Panašios prekės

Openbox SF-120 Openbox SF-120 Plačiau
Dreamsky TSF 40 Dreamsky TSF 40 0 Plačiau
Openbox SF-110 Openbox SF-110 Plačiau